You are here Alat Ukur - Instrument Professional Photometer

Alat Teknik - PD. Karya Mitra Usaha


Warning: strtotime() [function.strtotime]: It is not safe to rely on the system's timezone settings. You are *required* to use the date.timezone setting or the date_default_timezone_set() function. In case you used any of those methods and you are still getting this warning, you most likely misspelled the timezone identifier. We selected 'Asia/Krasnoyarsk' for 'WIB/7.0/no DST' instead in /home/teknikpm/public_html/libraries/joomla/utilities/date.php on line 56

Warning: date() [function.date]: It is not safe to rely on the system's timezone settings. You are *required* to use the date.timezone setting or the date_default_timezone_set() function. In case you used any of those methods and you are still getting this warning, you most likely misspelled the timezone identifier. We selected 'Asia/Krasnoyarsk' for 'WIB/7.0/no DST' instead in /home/teknikpm/public_html/libraries/joomla/utilities/date.php on line 198

Professional Photometer - Alat Teknik

Print

Mi404 Free & Total Chlorine
Professional Photometer
Mi404 Free & Total Chlorine - Professional Photometer - Alat Teknik

Applications:         
- swimming pool treatments        
- household cleaners,         
- dishwasher additives,        
- laundry powders/liquids         
- cooling water treatment products        
- all contain chlorine as an oxidizing biocide        
- drinking water contains residual chlorine        
        
Specifications :        
Free Chlorine Range    :    0.00 to 5.00 mg/L Cl2
Total Chlorine Range    :    0.00 to 5.00 mg/l Cl2  
Free Chlorine Resolution    :    0.01 mg/l (0.00 to 3.50 mg/l);
        0.10 mg/l (above 3.50 mg/l)  
Total Chlorine Resolution    :    0.01 mg/l (0.00 to 3.50 mg/l);
        0.10 mg/l (above 3.50 mg/l)  
Free Chlorine Accuracy    :    ±0.04 mg/l @1.50 mg/l
Total Chlorine Accuracy    :    ±0.04 mg/l @1.50 mg/l
Method adaptation of the USEPA method 330.5 & Standard Method 4500-Cl G         
Light Source tungsten lamp         
Light Detector silicon photocell and 525 nm narrow band interference filter         
Environment    :    Environment : 0 to 50°C / 32 to 122°F; max RH 100%
Battery Type    :    1 x 9V (included)
Auto-off    :    after 10 minutes of non-use
Dimensions    :    192 x 104 x 52 mm
Weight    :    380g

Mi404 is supplied complete:
- 2 cuvets,
- Reagents,
- Carrying case,
- Wiping tissue,
- 9V battery and instructions.

Mi405 Ammonia (Medium Range)
Professional Photometer
Mi405 Ammonia (Medium Range) - Professional Photometer - Alat Teknik

Applications:         
Ammonia detection in water treatment systems is particularly important for aquarium owners and fish farm operators.        
        
Specifications :        
Range    :    0.00 to 9.99 mg/l (NH3-N)  
Resolution    :    0.01 mg/l  
Accuracy    :    ±0.10 mg/l @5.00 mg/l  
Method    :    adaptation of Nessler method
Sorgente luminosa    :    Blue LED 466 nm  
Light Detector    :    silicon photocell & 466 nm narrow band interference filter
Environment    :    0 to 50°C / 32 to 122°F; max RH 100%
Battery Type    :    1 x 9V (included)
Auto-off    :    after 10 minutes of non-use
Dimensions    :    192 x 104 x 52 mm
Weight    :    380 g
Mi405 is supplied complete:
- 2 cuvets,
- Reagents for 100 tests,
- Carrying case,
- Wiping tissue,
- 9V battery and instructions.

Mi406 Free Chlorine
Professional Photometer
Mi406 Free Chlorine - Professional Photometer - Alat Teknik

Applications:         
- swimming pool treatments        
- household cleaners,         
- dishwasher additives,        
- laundry powders/liquids         
- cooling water treatment products        
- all contain chlorine as an oxidizing biocide        
- drinking water contains residual chlorine        
        
Specifications :        
Free Chlorine Range    :    0.00 to 5.00 mg/l Cl2
Free Chlorine Resolution    :    0.01 mg/l (0.00 to 3.50 mg/l);
    :    0.10 mg/l (above 3.50 mg/l)  
Free Chlorine Accuracy    :    ±0.04 mg/l @1.50 mg/l
Method adaptation of the USEPA method 330.5 & Standard Method 4500-Cl G         
Light Source    :    tungsten lamp
Light Detector    :    silicon photocell and 525 nm narrow band interference filter
Environment    :    0 to 50°C / 32 to 122°F; max RH 100%
Battery  Type    :    1 x 9V (included)
Auto-off after    :    10 minutes of non-use
Dimensions    :    192 x 104 x 52 mm
Weight    :    380 g
Mi406 is supplied complete with :        
- 2 cuvets,         
- Reagents,         
- Carrying case,         
- Wiping tissue,         
- 9V battery and instructions.      

Mi407 Ammonia (Low Range)
Martini Instruments Professional Photometer
Mi407 Ammonia (Low Range) Martini Instruments Professional Photometer

Applications:         
Ammonia detection in water treatment systems is particularly important for aquarium owners and fish farm operators        
        
Specifications :        
Ammonia Range    :    0.00 to 3.00 mg/l (NH3-N)
Ammonia Resolution    :    0.01 mg/l
Ammonia Accuracy    :    ±0.04 mg/l @1.50 mg/l
Method  adaptation     :    of Nessler method
Light Source    :    Blue LED 466 nm
Light Detector    :    silicon photocell and 466 nm narrow band interference filter
Environment    :    0 to 50°C / 32 to 122°F; max RH 100%
Battery Type    :    1 x 9V (included)
Auto-off    :    after 10 minutes of non-use
Dimensions    :    192 x 104 x 52 mm
Weight    :    380 g
        
Mi407 is supplied complete with :         
- 2 cuvets,         
- reagents,         
- Carrying case,         
- Wiping tissue,         
- 9V battery and instructions      

Mi408 Iron (High Range) - Professional Photometer
Mi408 Iron (High Range) - Professional Photometer - Alat Teknik

Applications:
Iron is naturally present in water supplies and its presence in both potable & industrial applications is regarded as objectionable.

Specifications :
Iron Range    :    0.00 to 5.00 mg/l Fe
Iron Resolution    :    0.01 mg/l
Iron Acuuracy    :    ±0.03 mg/l @1.50 mg/l
Method adaptation of the USEPA method 330.5 & Standard Method 4500-Cl G         
Light Source    :    Tungsten lamp
Light Detector    :    silicon photocell and 525 nm narrow band interference filter
Environment    :    0 to 50°C / 32 to 122°F; max RH 100%
Battery Type    :    1 x 9V (included)
Auto-off after    :    10 minutes of non-use
Dimensions    :    192 x 104 x 52 mm
Weight    :    380 g
        
Mi408 is supplied complete with :
- 2 cuvets,
- reagents,
- Carrying case,
- Wiping tissue,
- 9V battery and instructions

Mi411 Free & Total Chlorine and pH Martini
Professional Photometer
Mi411 Free & Total Chlorine and pH Martini - Professional Photometer - Alat Teknik

Applications:
Chlorine is the most commonly used water disinfectant.        
Applications vary from treatment of drinking water and wastewater to pool and spa sanitization and food processing to sterilization.
        
Specifications :
Free Chlorine Range    :    0.00 to 5.00 mg/l Cl2
Total Chlorine Range    :    0.00 to 5.00 mg/l Cl2
pH Range    :    6.5 to 8.0 pH
Free Chlorine Resolution    :    0.01 mg/l (0.00 to 3.50 mg/l);
                                       :    0.10 mg/l (above 3.50 mg/l)
Total Chlorine Resolution    :    0.01 mg/l (0.00 to 3.50 mg/l);
                                       :    0.10 mg/l (above 3.50 mg/l)
pH Resolution    :    0.1 pH
Free Chlorine Accuracy    :    ±0.04 mg/l @1.50 mg/l
Total Chlorine Accuracy    :    ±0.04 mg/l @1.50 mg/l
pH Accuracy    :    pH ±0.1 pH @7.2 pH
Free Chlorine Method    :    adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G
Free Chlorine Method    :    adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G
pH Method    :    adaptation of the phenol red method
Light Source    :    tungsten lamp
Light Detector    :    silicon photocell and 525 nm narrow band interference filter
Environment    :    0 to 50°C / 32 to 122°F; max RH 100%
Battery Type    :    1 x 9V (included)
Auto-off    :    after 10 minutes of non-use
Dimensions    :    192 x 104 x 52 mm
Weight    :    380 g

Mi411 is supplied complete  with:
- 2 cuvets,
- liquid reagents for 100 tests,
- Carrying case, wiping tissue,
- 9V battery and instructions.

Mi412 Phosphate (Low Range)
Martini Instruments Professional Photometer
Mi412 Phosphate (Low Range) Martini Instruments Professional Photometer - Alat Teknik

Applications:
Phosphates are present in natural waters and at concentrations typically found, do not pose any specific health threats to humans.
However, excessive contamination of water courses from agricultural fertilizer run off or wastewater/effluent discharge can promote excessive algae or plant growth.         
        
Specifications :        
Phosphate Range    :    0.00 to 2.50 mg/l PO4
Resolution Range    :    0.01 mg/l
Accuracy Range    :    ±0.04 mg/l @1.00 mg/l
Method    :    adaptation of Ascorbic Acid method
Light Source    :    tungsten lamp
Light Detectorfilter     :    silicon photocell and 610 nm narrow band interference filter
Environment    :    0 to 50°C / 32 to 122°F; max RH 100%
Battery Type    :    1 x 9V (included)
Auto-off    :    after 10 minutes of non-use
Dimensions    :    192 x 104 x 52 mm
Weight    :    380 g

Mi413 Free & Total Chlorine (High Range)
Professional Photometer
Mi413 Free & Total Chlorine (High Range) - Professional Photometer

Applications:
- Swimming pool treatments,         
- Household cleaners,
- Dishwasher additives,         
- Laundry powders/liquids        
- Cooling water treatment products        
- All contain chlorine as an oxidizing biocide.        
- Drinking water contains residual chlorine        
        
Specifications :        
Free Chlorine Range    :    0.00 to 10.00 mg/l Cl2
Total Chlorine Range    :    0.00 to 10.00 mg/l Cl2  
Free Chlorine Resolution    :    0.01 mg/l (0.00 to 3.50 mg/l);
    :    0.10 mg/l (above 3.50 mg/l)  
Total Chlorine Resolution    :    0.01 mg/l (0.00 to 3.50 mg/l);
    :    0.10 mg/l (above 3.50 mg/l)  
Free Chlorine Accuracy    :    ±0.10 mg/l @5.00 mg/l
Total Chlorine Accuracy    :    ±0.10 mg/l @5.00 mg/l
Method    :    adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G
Light Source    :    tungsten lamp
Light Detector    :    silicon photocell and 525 nm narrow band interference filter
Environment    :    0 to 50°C / 32 to 122°F; max RH 100%
Battery Type    :    1 x 9V (included)
Auto-off    :    after 10 minutes of non-use
Dimensions    :    192 x 104 x 52 mm
Weight    :    380 g
Mi413 is supplied complete:
- 2 cuvets,
- Reagents,
- Carrying case,
- Wiping tissue,
- 9V battery and instructions

Mi414 Chloride Martini Instruments Professional Photometer
Mi414 Chloride Martini Instruments Professional Photometer

Applications:
Chlorides are used by the water treatment professional to determine cycles of concentration in low pressure boilers and cooling systems. It is essential to monitor chloride concentrations in boiler systems to prevent metal parts being damaged. In high levels, chloride can corrode stainless steel.        
        
Specifications :
Chloride Range    :    0.00 to 20.00 mg/l Cl¯
Chloride Resolution    :    0.01 mg/l
Chloride Accuracy    :    ±0.4 mg/l @10.0 mg/l
Method : Adaptation of mercury (II) thiocyanate method         
Light source Blu LED 466 nm         
Light Detector    :    silicon photocell and 466 nm narrow band interference filter
Environment    :    0 to 50°C / 32 to 122°F; max RH 100%
Battery Type    :    1 x 9V (included)
Auto-off    :    after 10 minutes of non-use
Dimensions    :    192 x 104 x 52 mm
Weight    :    380 g
Mi414 is supplied complete:
- 2 cuvets,
- reagents,
- Carrying case,
- Wiping tissue,
- 9V battery and instructions


Professional Photometer - Alat Teknik - Alat Instrument - Alat Civil - Alat Safety

Web Officer

Kami siap membantu Anda

Toko Glodok Teknik / Safety

Jl. Hayam Wuruk 127 Gedung Lindeteves Trade Centre (LTC Glodok),
Lantai 2 Blok C3 No. 6-7, Jakarta

  • Tel: (+62) 21-30063681
  • Fax: (+62) 21-62320340
  • Email: k000333111@yahoo.com